SAB® PRO 300 Membrane & Screed

https://sab-gate.com/web/image/product.template/1371/image_1920?unique=c54807f

ROOF WATERPROOFING / SAB® PRO 111 (MEMBRANE) SYSTEM:
1-Execute slope corners (skirting) 20cm*20cm along with the barbate.
2-Execute a Cavity 1.5*1.5 cm, along with the barbate over the skirting.
3-One coat of bituminous primed surface.
4-One layer of Membrane APP 4mm thick, 180 g/m2
5-Screed Concrete, 80mm Avg. 20/N - OPC 300 kg/m3
6-Execute slope corners 20cm*20cm along with the barbate.
7-Remove the ridges, then fill them with a sponge.
8-Supply and apply 1.5x1.5 cm mastic over the sponge.