Sealing of construction joints For the successful application of Hydroseal P in construction joints, the profile has to be placed into the center of the reinforcement or at least 10 cm away from the concrete flanks.
It has to be adhered fully with Polyseal PP / Polyseal Swell / Bitubond N to the substrate.
If necessary the profile can also be nailed onto the concrete.
It has to be sure that the profile cannot change its position while concreting. Rough surfaces should be smoothened before adhering the profile.
This can be achieved with the application of Polycrete concrete repair products or with the sealant Polyseal Swell which develops in contact with water expansion to seal any gap or undulations between the surface and Hdyroseal P.
Jointing of end and side laps Joints and lap-over areas are to be fixed by means of Polyseal Swell / Polyseal PP / Bitubond N.
Sealing of precast concrete segments If used for sealing of precast concrete elements it is recommended to create a notch in the segments.
The applied profile is chosen so that the elements create already at assembling a prestress.
A proper plugging can be achieved with mounting cements like Polyquick FS or a permanently elastic sealant e.g. Polyseal PP.